Water leak Detection | Gas leak detection | Pipe and Cable location | Object Detection

SePem® 01 Download PDF

Stationary Noise Loggers For the Early Recognition of Leaks in Water Supply Networks

For the early detection of leaks in water supply networks

SePem® 01 The longer it takes to identify that a network is leaking the more revenue is lost and the greater the loss of precious water resources. In addition to the more conventional methods of leak detection the installation of permanent noise loggers from the SePem® family of instruments, has proved to be a cost effective tool in early identification of water loss. By permanently monitoring sections of the system, which have previously been proven leak free, SePem® 01 will alert you when a leak does develop. SePem® 01 is a highly sensitive piezo accelerometer noise microphone and data logger that transmits its stored information to the Master control unit via radio.


SePem® 01 - deployment

SePem® 01 noise loggers are mounted, by magnetic contacts, onto valves or underground fire hydrants. The magnet can be mounted on the long or the short side of the logger body allowing it to be installed horizontally or vertically. The low profile presented by the horizontal mounting offers great flexibility and a wide range of installation positions.

The SePem® 01 can fit in particularly tight spaces. Even with very low clearance heights between the top of the valve and the underside of the cover. The magnet can be located on the SePem® 01 body eccentrically so it can even fit onto decentralised spindles. SePem® 01


SePem® 01-Master im Einsatz
  • The loggers record sound over a defined period, either on a repeat basis or just the once, (user programmable). The results are transmitted, at pre defined times, (user decides when best), to the Master.
  • At regular intervals, or when an increase in water usage is identified (increased night line readings), the loggers are interrogated by the Master from the safety of your vehicle by a “drive by” the loggers.
  • If there is a leak the SePem® 01 will send an alarm which is clearly indicated on the Master, both visually and audibly. Users require no special training. There is no PC or post measurement analysis required.

  • SePem® 01


    The basic information transmitted to the Master is the Minimum Noise Level, which is the quietest noise recorded during the preceding measuring cycle. Normal customer usage fluctuates up and down however leaks never become quiet. If the minimum noise level has increased over its normal level it is likely to be a leak that is the cause.

    SePem® 01 - Master

    The SePem® 01 - Master is used to programme and read the loggers’ parameters by a two way radio connection. All settings are freely selectable by the user. No PC is required at any point!
    It offers even the less experienced operator the ability to receive quick and reliable leak results due to the simple and intuitive menu structure combined with the easy to use “jog dial” & soft keys.

    At its simplest that is how easy the SePem 01 is to use but it can do a lot more... SePem® 01


    SePem® 01 - As a survey tool

    The SePem® 01 - may also be used as a leak survey tool.
    Due to the acoustical nature of leak location background noise very often makes it impractical to listen for leaks during the day. This means that the only alternative is to work at night, which has many drawbacks amongst them being it is expensive to pay staff night rates and there can be health and safety implications, particularly in busy cities. By using the SePem® 01 these problems are overcome. The loggers can be programmed to:
    • start logging immediately or up to 30 days in the future
  • to log continuously, or during a window to best suit your local conditions- it may not be the best idea to record at 0200-0400 in the nightclub district but it may be the quietest time in the residential areas
    • to log at intervals from 1 second to 1 hour
    • to log once and then turn itself off
  • to log permanently over 24 hours always storing the minimum noise level recorded during the last measuring period
  • Alarms can be set automatically using a built in algorithm or programmed by the user. This means that meaningful reading can be taken over just one night

  • SePem® 01


  • to transmit stored information at times to best suit your working practices. What is the point in having the radio transmitting and using valuable battery capacity over the weekend when you are not going to carry out any surveys?

  • SePem® 01


    Online real time noise measurement

    The SePem 01 uses bi-directional radio communication which means an online real time noise level can be seen without getting out of the safety of your vehicle. This function can be used to decide if a measuring point is suitable prior to leaving a logger in position; if the measuring point is reading high levels before you put the logger out it is probably already leaking!

    SePem® 01


    If after carrying out a survey or “drive- by” an alarm is shown you can look at the current real time noise over the radio link - If the noise level has disappeared (unlikely) you may conclude it was usage during the logging period and it may not indicate a leak.; if is still noisy you can be confident it is a leak.

    Patrol or “drive-by” information

    Routine “Drive-by’s” can provide more information than simple “Leak No leak”. The Master displays:

    SePem® 01


    This screen displays the noise levels logged throughout the last measuring period.

    SePem® 01 The recorded noise level was continuously high during the measuring period - High probability of a leak


    Long life loggers...

    All battery powered loggers have a finite life. Some other loggers on the market, due to their method of construction, must be thrown away when the batteries have expired; SePem® 01 noise loggers are different. Under standard operating conditions SePem® 01 will last at least 5 years, even longer with different settings. However there is no need to throw it away when the battery does expire; it can be fully refurbished and given another lease of life at that time. When you add this into the whole of life costs of the SePem® 01 it makes financial as well as technological sense.

    Features Master

  • Innovative information handling concept by "jog dial" and soft keys as well as intuitive menu guidance SePem® 01-Master

  • Flexible carrying options with fold out supporting handle

  • Visual (red flashing light & display) & audible warning of leak for vehicle drivers attention

  • Large internal memory

  • List of any “missed” loggers from “drive-by” patrol

  • Strongest frequency of recorded “noise” is displayed

  • Powered by 4 rechargeable or disposable batteries: AA - R6, or by 12V DC, from cigar lighter, or hard wired

  • Operation from the 12 V supply of the car by direct cable link

  • Operating time min. 8 hours when rechargeable batteries are used

  • Protection according to IP 54

  • Operating temperature: -10 °C ... +50 °C

  • Storage temperature: -20 °C ... +70 °C

  • Weight approx. 1 kg

  • Dimensions (W x D x H) in mm: 148 x 57 x 205 (253 with handle)
  • Vehicle mounting bracket available
  • SePem® 01


    Features SePem® 01 Logger

  • Tough & durable polished die-cast aluminium housing - Mechanical damage highly unlikely

  • Gold plated aerial connection- Uninterrupted radio transmissions, even out of deep boxes,- Does your current logging technique miss loggers or do you often have to leave your vehicle to read them?

  • No rust magnets - clearer noise path for microphone; improved sensitivity

  • Horizontal or vertical installation. Attachment is by a magnet in a sliding track which means it can even fit into boxes with eccentric valves

  • Digital high-performance radio transmission

  • Bi-directional communications - errors in transmission are automatically corrected

  • Power supply by built-in Lithium battery

  • Operating time: typically 5 years, with daily radio transmission (with radio transmission set to once a week this time increases significantly)

  • Protection according to IP68 (submersible down to 1 m)

  • Dimensions (W x D x H) in mm: 108 x 51 x 50

  • Installation depth horizontal in mm: 67

  • Installation depth vertical in mm: 125
  • SePem® 01